DC network rig(DC electric)& transformation

 

Energy saving, environmental protection, efficient, this is the network rig. Network rig can reduce the noise, save drilling cost, reduce the labor intensity of workers, not only save money, fuel-efficient, labor-saving, but also improve the safety level. Network rig, your good helper.

1. System components:
Dc network rig system is based on the original diesel generator power supplying DC electric on the electric control system, and not changing the original power supply reliability, under the premise of taking the electric power grid as a power supply substitute of the formation of the diesel generator power supply and rig electrical control system.
Our electricity system has the protection, control, monitoring and measurement, and the function is exactly same with the LDB signal system with high pressure room. DC network rig consists of six components, including: 10kv grid, 600V generator, SCR room, one KP module with network high-voltage distribution, one transformer KT module and one two-end network switch Q module. As below:
 
When using the turbodrill, it is a need to have a larger active power and reactive power, voltage fluctuation is also more serious, so that we can use circumscribed reactive compensation and three end type module TSF network switching device to increase the amount of reactive power compensation and improve the quality of voltage. As below:
2. Application
This network system is suitable for network transformation project of ZJ70DB fully electric variable-frequency drilling rig and ZJ70D fully electric DC drilling rig. After using this product, drilling rig no longer use diesel generator but power of 10kV grid thus lower diesel consumption of high price, reduce CO2 emission and greatly lower noise of well site. The direct benefit using power instead of diesel is able to reduce (20 to 30)% drilling energy consumption cost, if the cost, like operation, maintenance, spare parts, fuel oil transportation etc of diesel generating set is accounted, the overall reduction of drilling power cost is around (20~35)%.
3. Basic mechanical design feature
Table 1 main technical parameters of DC network rig’s network system
10kV DC electric network system essential parameter
Model
DH.KYB1F-10/0.6
Transformer capacity
2500~4000 kV
Max. rated voltage
12kV
Capacity of MSVC
1200kVAr
Rated operational voltage
10kV
Harmonic compensation current
200~600A
Shell coefficient
K=10
Dimensions
L11570*W2900*H2940
Protection level of distribution room
IP55D
Total weight
26t
The default configuration main parameters of transformer
HJB
SCZ10-2500-10/0.6
Rated capacity
2500kVA
On-load changer range
10±4*2.5%/0.6kV
Impedance voltage
6.0%
resistance to heat class
H
Winding coupling group
D,d-0
high-voltage switch cabinet main parameters
Model
TZ.XGN1-12/630-20
Rated voltage
10kVA
XGN15-12FV/630-20
Rated current
630A
Rated short-circuit breaking current
20kA
Short-term resistance current
20kA/4s
Table 2 Different rig and transformer capacity, reactive power compensation and harmonic compensation current capacity supporting table
Rig model
120DB
90DB
70DB
70D
Transformer capacity (kVA)
4000
3150
2500
2500
Reactive power compensation capacity (kVAr)
2000
1600
1200
2000
Filter harmonic compensation current (A)
800
600
300
600
 
 
 
 
 
 
4. Sales
    Process: First, submit the data form according to the requirements of our company.
                    Second, overseas field survey and site measurement.(negotiation)
                    Third, our company submit the design.
                    Forth, production delivery in three month.
                    Fifth , site installation and commissioning.
                    Sixth, feedback after one year.
 
5. Customer service
      Within guarantee period, we supply free after service. After guarantee period, we offer remote technical service and extensive service.
 
      Thanks, we look forward to your inquiry.