Mechanical drilling rig network system is suitable is suitable for network transformation project of ZJ70L, ZJ50L, ZJ40L and below level’s mechanical drilling rig of chain box drive type. After using this product, drilling rig no longer use diesel engine and diesel generating set but DC motor hydraulic coupler set driven by power to drive carriage directly, use network to drive other 400V equipment in well site, thus lower diesel consumption, reduce CO2 emission and greatly lower noise of well site.
As a result of its excellent speed regulating characteristics of DC motor excitation, the network system can adapt to all drilling conditions, especially under the condition of low speed and high torque, its efficiency is much higher than the efficiency of diesel engine. Therefore, doing network transformation to LDB drilling rig, the effect of energy saving and emission reduction is particularly evident. According to our tracking statistics, The direct benefit of LDB network transformation is able to reduce (45 to 65)% drilling energy consumption cost, if the cost, like operation, maintenance, spare parts, fuel oil transportation etc of diesel generating set is accounted, the overall reduction of drilling power cost is around (50 to 70)%.
3. Mainly technical performance
Table 1 Mechanical rig comprehensive network system main technical parameters | 10kV full electric network system essential parameter | Model | DH.KZH-10/0.6/0.4 | Main transformer capacity | 1600 kVA | Max. rated voltage | 12kV | Turn for transformer capacity | 630 kVA | Rated operational voltage | 10kV | Capacity of MSVC | 1000 kVAr | Shell coefficient | K=10 | Dimensions | L11570*W2900*H2940 | Protection level of distribution room | IP55D | Total weight | 26t | transformer main parameters | HJB | SCZ10-1600-10/0.6 | Rated capacity | 1600kVA | On-load changer range | 10±4*2.5%/0.6kV | Impedance voltage | 6.0% | resistance to heat class | H | Winding coupling group | D,d-0 | high-voltage switch cabinet main parameters | Model | TZ.XGN1-12/630-20 | Rated voltage | 10kV | XGN15-12FV/630-20 | Rated current | 630A | Rated short-circuit breaking current | 20kA | Short-term resistance current | 20kA/4s | |
|
4. Sales
Process: First, submit the data form according to the requirements of our company.
Second, overseas field survey and site measurement.(negotiation)
Third, our company submit the design.
Fourth, production delivery in three month.
Fifth , site installation and commissioning.
Sixth, feedback after one year.
5. Customer service
Within guarantee period, we supply free after service. After guarantee period, we offer remote technical service and extensive service.
Thanks, we look forward to your inquiry.